Comparative Study for Corrosion Resistance of Ferrous and Non-ferrous Pipes Immersed in Magnetized Water

Authors

DOI:

https://doi.org/10.5755/j02.ms.36247

Keywords:

AZ31, galvanized steel, magnetized water treatment, corrosion

Abstract

This study aims to investigate the corrosion resistance of galvanized steel (GS) and AZ31 pipe materials immersed in a magnetized water treatment (MWT) applied river water source. The potentiodynamic corrosion test results showed that a better corrosion rate is obtained by the AZ31(corr.rate: 0.0442 mm/y) specimen than GS (corr.rate: 0.0764 mm/y) due to the passivation efficiency resulting from the calcite and MgO particles on the surface.

Downloads

Published

2024-09-22

Issue

Section