Comparative Study for Corrosion Resistance of Ferrous and Non-ferrous Pipes Immersed in Magnetized Water
DOI:
https://doi.org/10.5755/j02.ms.36247Keywords:
AZ31, galvanized steel, magnetized water treatment, corrosionAbstract
This study aims to investigate the corrosion resistance of galvanized steel (GS) and AZ31 pipe materials immersed in a magnetized water treatment (MWT) applied river water source. The potentiodynamic corrosion test results showed that a better corrosion rate is obtained by the AZ31(corr.rate: 0.0442 mm/y) specimen than GS (corr.rate: 0.0764 mm/y) due to the passivation efficiency resulting from the calcite and MgO particles on the surface.
Downloads
Published
Issue
Section
License
The copyrights for articles in this journal are retained by the author(s), with first publication rights granted to the journal. By virtue of their appearance in this open-access journal, articles are free to use with proper attribution in educational and other non-commercial settings.